Product imagery shown for reference. Confirm the exact configuration before ordering.
AST-45D %O2 Sensor Replaces Analox 9100-9212-5A/5AD O2 Sensor
AST-45D %O2 sensor replaces Analox Model 9100-9212-5A/5AD, AII Model PSR-11-37-D3 and IT Gambert D-08. This sensor fits in Analox Mini O2 and Analox Mini O2-II analyzers. AST-45D %O2 sensor can measure oxygen between 0-100%. Signal output of the sensor 23-29mV in air. The outer sensor casing has slip-on…
Technical information
Product details
Technical overview
AST-45D %O2 sensor replaces Analox Model 9100-9212-5A/5AD, AII Model PSR-11-37-D3 and IT Gambert D-08. This sensor fits in Analox Mini O2 and Analox Mini O2-II analyzers. AST-45D %O2 sensor can measure oxygen between 0-100%. Signal output of the sensor 23-29mV in air. The outer sensor casing has slip-on front end. Expected sensor life in air is 42 months at ambient temperature and pressure. Proprietary electrolyte formulation and anode structure of AST sensors ensure full utilization of Pb anode, thus providing longer life without signal drift and minimizing periodic calibration requirement. AST brand sensors are designed and manufactured in the USA.
Applications and guidance
Advanced Sensor Technology
AST-45D % O₂ Sensor – Replacement for Analox Mini O₂ Analyzers
The AST-45D %O2 sensor from Applied Sensing Technologies is designed as a direct replacement for the Analox 9100-9212-5A/5AD oxygen sensor, the AII PSR-11-37-D3 sensor, and the IT Gambert D-08 sensor.
This sensor fits directly into Analox Mini O2 Analyzer and Analox Mini O2-II Analyzer instruments. Because it is a form-fit replacement, users can install the sensor easily without modifying the analyzer.
The AST-45D %O2 sensor measures oxygen concentrations from 0 to 100%, which makes it suitable for a wide range of gas analysis applications. In addition, the sensor provides a signal output of 23–29 mV in air, ensuring reliable performance with compatible analyzers.
The sensor features an outer casing with a slip-on front end, which allows quick and secure installation.
Moreover, the sensor incorporates a proprietary electrolyte formulation and optimized anode structure. This design ensures full utilization of the lead (Pb) anode, which helps extend the operating life of the sensor. As a result, the sensor delivers stable output with minimal signal drift, reducing the need for frequent calibration.
Under ambient temperature and pressure in air, the expected operating life of the AST-45D sensor is approximately 42 months.
Finally, AST brand oxygen sensors are designed and manufactured in the United States by Applied Sensing Technologies, ensuring reliable quality and consistent performance.
AST-45D Replaces
- Analox 9100-9212-5AD
- AII PSR-11-37-D3
- IT Gambert D-08
Specifications and compatibility references
Application support
Not sure this is the right sensor?
Send the existing sensor or analyzer model and AST will help confirm the correct replacement.